Recall (Maintenance Period)

The Recalls tab on the Practice Defaults screen contains the recall periods used by the Induction and Maintenance periods. Anticoagulation Manager takes into account seven INR results within range when working out the recall periods in weeks.

The following recall intervals are used:

  • One latest INR within range the recall interval is set to One week
  • Two latest INR's within range the recall interval is set to Two weeks
  • Three latest INR's within range the recall interval is set to Four weeks
  • Four latest INR's within range the recall interval is set to Six weeks
  • Five latest INR's within range the recall interval is set to Eight weeks
  • Six latest INR results within range equals a Ten week recall
  • Seven latest INR results within range equals a Twelve week recall